Thyssenkrupp Levant Stair Lift Installation Manual Top Guidelines
When installing the top limit assembly, verify the "dead man" logic. On the Levant, releasing the joystick should cut power immediately. However, at the top, the limit switches physically break the drive circuit. Installers must test the switch actuation by manually depressing them with a finger while the chair is in transit (in a controlled test environment) to ensure the braking resistors engage correctly. thyssenkrupp levant stair lift installation manual top
The Levant uses a track system that must be mounted securely to the stair treads, not the wall. The manual provides a specific template for drilling. The "top" of the rail often requires cutting to length on-site. The manual specifies the exact angle for the cut to ensure the carriage sits level when parked at the top. Installers must test the switch actuation by manually
A standard installation typically follows these sequential phases: Preparation and Measurements Measure the nose-to-floor distance , tread, and rise of the stairs. The "top" of the rail often requires cutting
Mechanical stops and electronic limit cams must be set to prevent the drive unit from over-traveling. Upper Limit Cam