Magnetic system with multiple intensity levels adjusted via a tension knob or console.
The BC 5700 series (including the BC-5700G and BT-5700 variants) is engineered for stability and ease of use. Body Sculpture Bc 5700 Magnetic Bike Manual
| Problem | Likely Cause | Solution (from manual) | | :--- | :--- | :--- | | Console won’t turn on | Dead batteries or loose wire | Replace AAA batteries. Check that the sensor wire is fully inserted into the console. | | Erratic or zero readings | Magnet sensor gap is too wide | Adjust the position of the reed switch (magnetic sensor) so it passes within 1-2mm of the magnet on the flywheel. | | Pedaling feels jerky | Flywheel imbalance or loose belt | Contact customer service. Do not open the main belt housing yourself. | | Squeaking noise during use | Loose bolts or lack of lubrication on pedal threads | Tighten all visible bolts with the included Allen key. Apply a drop of light oil to pedal threads. | | Resistance knob does nothing | Magnetic unit is stuck or cable is disconnected | Open the tension cable housing (see manual diagram 7) and ensure the cable is attached to the magnet arm. | Magnetic system with multiple intensity levels adjusted via
Many versions include several pre-set workout programs (often 17, including 1 manual, 8 presets, and target heart rate settings). Monitoring: Check that the sensor wire is fully inserted
A: Yes. Hold down the MODE and SET buttons simultaneously for 5 seconds. This will reset the total distance back to zero.